Development of a lateral flow device for rapid simultaneous multiple detections of some common bacterial causes of bovine mastitis
Keywords:
Bovine mastitis; bacterial pathogens; lateral flow testAbstract
Objective: This work was conducted for the development of a 5-combi lateral flow immunochromatographic kit (LFK) for rapid and simultaneous identification of the common bacterial causes of bovine mastitis. The following pathogens are the identification targets of this kit: Escherichia coli, Staphylococcus aureus, Klebsiella pneumoniae, Streptococcus agalactiae, and Streptococcus pyogenes in milk samples from suspected bovine mastitis cases. The conventional microbiological identification of these agents is not only time-consuming and requires a fully equipped laboratory but also requires experienced personnel. Materials and Methods: Rabbit polyclonal antibodies (PAbs) specific to the antigenic components of the selected pathogens were prepared, and the pathogen-specific IgG was separated, purified, and conjugated with nanogold that was laid on the conjugate pad. Guinea pig PAbs specific to the microbial antigens of the selected pathogens were prepared, and their IgG content was separated, purified, and used as a capture antibody in the test (T) line on the nitrocellulose (NC) strips. Goat anti-rabbit IgG antibodies were used to capture the rabbit antibodies in the control (C) line of NC strips. The kit was held in a device comprising five strip-holding channels for the abovementioned five bacterial species antigens. The developed LFK was evaluated, and its sensitivity and specificity were determined. Results: The developed kits were applied for the examination of bovine milk samples from suspected mastitis cases, and the average sensitivity, specificity, and accuracy of 5-combi LFK for the detection of the five selected bacterial species compared to bacteriological examination (gold standard test) were 93.90%, 80.83%, and 90.53%, respectively. The minimal microbial count that gave positive results using the developed LFK was 103 colony forming unit/ml. Treatment of the milk samples with an application buffer and its pre-incubation in trypticase soy broth for 6 h at 37°C before testing significantly increased the sensitivity of the prepared LFK. The developed kit proved simple and convenient, and the results could be obtained in less than 10 min.
J. Adv. Vet. Anim. Res., 10(2): 292–300, June 2023
Downloads
8
7
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Rafik Hamed Sayed, Rafik Twfik Soliman, Shaimaa Abdelall Elsaady

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Authors who publish with this journal agree to the following terms:
Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).